Applications

High Throughput Screening

Assay Development

PCR / Sequencing

Bead Dispensing

Cell Dispensing

Protein Crystallography

MALDI

IC50's

Medical Diagnostic Kits

Technology Briefings

High Precision, Non-Contact Dispensing

Low-Volume Dispensing with the Nanodrop

 

Nanodrop™ Express

Innovadyne Technologies introduces the 16-channel Nanodrop™ Express, our fastest benchtop system -- a complete high-throughput solution for low volume, high-precision pipetting.

The Nanodrop Express doubles the dispense capacity and halves the aspirate time of a Nanodrop II. The Nanodrop Express can be configured with one- or two-plate stage modules, and interchangeable 1x16 or 2x8 tip heads specialized for reagent dispensing and 96-to-384 transfers, respectively. For reagent addition, 8 individual tips can access any well of a standard SBS plate, enabling complex method development and design.

The Nanodrop Express aspirates and dispenses a broad range of liquids, including DMSO, and features the Nanobuilder© software system that enables a wide range of applications and data manipulation. Innovadyne’s patented technology isolates the solenoid dispense actuators from the sample path. This assures long life and easy, low-cost maintenance, even with regular use of difficult suspensions such as proteins, cells and YOx beads.

Features

  • Non-contact and contact dispense

  • Exceptional dynamic range (nanoliter to milliliter)

  • Interchangeable 1x16 tip (for reagent dispensing and 384+ well plates) and 2x8 tip (for 96-to-384 transfers) heads

  • Multiple reagent addition

  • Aspirate and dispense with individual channel articulation

  • Sample transfer and bulk reagent addition on the same platform

  • Valve-free fluid path for outstanding reliability

  • FEP, SS, sapphire wetted parts compatible with commonly used solvents

  • 96-, 384-, and 1536-well plate formats; deep-well and crystal plates supported

  • Modular, raised, removable plate nests enable flexible configuration

  • 1-plate nest and 2-plate nest stages available

  • Easy to program, easy to automate

  • Simple cleaning and maintenance

Applications

Protein Crystallography

  • Coarse and fine screen creation

  • Mother liquor transfer

  • Protein additions

  • Hanging and sitting drop

HTS

  • Sample transfer

  • Reagent addition

Assay Development - Miniaturization

Cell-based Assays

  • Cell plating

  • Cell dosing

Bead-based Assays

  • SPA bead assays

  • YOx bead assays

  • Polystyrene bead assays

PCR

  • Template transfers

  • Cocktail addition

  • Sequencing

MALDI Plate Spotting

  • Oligo QC

  • Proteins

Performance Specifications


96, 96 deep well, 384, 384 deep well, 1536, 1536 low profile, crystallography plates (Note: 96-well plates require the 2x8 head)

1 or 2

0.1 mm

Compound transfer (contact/non-contact), single tip reagent addition, 8-tip reagent addition

All the same volumes, independent

All the same volumes, independent

0.1 - 500 µL

0.1 - 80 µL (non-contact)
25 - 500 µL (contact)

CV 10% at 100 nL
CV 7% at 200 nL
CV 5% at 1 µL

±10% at 100 nL
±7% at 200 nL
±5% at 1 µL

1.44 µL/channel at 1 µL across
384-well plate

500, 1000 µL

10 s/transfer
(**2 reagent addition and 384/1536 1 reagent addition times forthcoming**)

Configuration Options


Part No.

Description

Nanodrop Express fluidics module (required)

1-plate stage module

2-plate stage module

1x16-tip head

2x8-tip head

Technical Specifications


Dimension

Fluidics
Module

1-Plate
Stage Module

2-Plate
Stage Module

33.0 cm
(13 in)

32.3 cm
(12.7 in)

32.3 cm
(12.7 in)

56 cm
(22 in)

24.6 cm
(9.7 in)

24.6 cm
(9.7 in)

44.5 cm
(18 in)

37.5 cm
(14.75 in)

53.6 cm
(21.1 in)

22 kg
(50 lb)

11.3 kg
(25 lb)

13.4 kg
(29.5 lb)

 

10 to 40°C, 80% RH

Standard grade helium (99.7% pure)

304 SS, sapphire

Custom, deep well plates

Ethernet, Nanobuilder software GUI

Nanobuilder component library

 




Nanodrop Express

Enlarge

Free! Innovadyne Information Kit