Platforms

Nanodrop™ I

Nanodrop™ ExtY

Nanodrop™ II

Nanodrop™ Express

Screenmaker™ 96+8

Platemaker™ HTS

Application Notes

Miniaturizing PCR with the Nanodrop

Technology Briefings

High Precision, Non-Contact Dispensing

Low-Volume Dispensing with the Nanodrop

 

molecular target solutions at Innovadyne Technologies

Innovadyne's PCR/sequencing platforms dispense template DNA at low volume and elaborate molecular target-pair maps for RT-PCR protocols. Innovadyne's technology enhances PCR based methodologies by facilitating reaction miniaturization. Reductions in both reagent and sample consumption not only lower costs, but also increase scalability, further enabling genome-wide approaches. Common applications include SNP analysis, QPCR, and molecular diagnostics protocols.

Central to reaction miniaturization is Innovadyne's ability to precisely deliver low volumes of both template and primers via non-contact dispensing. Accurate dispensing at low volumes permits direct linear reduction of reaction volumes and reagent use without dilution, thus maintaining optimal kinetics and assay performance. 20-to-50 fold reductions in total reaction volumes have been realized without compromise to data quality. Opportunities for carryover in the reaction assembly process are inherently minimized with Innovadyne's isolated microsolenoid valve design and the nature of non-contact dispensing further enhance its applicability to amplification-based methods.. Straightforward wash routines may be employed to eliminate carryover where contact occurs.

Flexible aspirate and dispense programmability, such as single-tip, random access pipetting, augments Innovadyne's broadcast reagent capabilities for applications such as the addition of multiple biomarkers to a single plate.

In the application note "Miniaturizing PCR with the Nanodrop," we compared a traditional liquid handling robot dispensing 10 µL (total volume) amplification reactions in a 384-well format against a Nanodrop assembling 1.25µL reactions using the same components. The data showed that the Nanodrop delivers comparable results while significantly reducing reagent costs and sample consumption.

 

Traditional Liquid Handler, 10 µL Assay

Nanodrop, 1.25 µL Assay

Features (all platforms)

  • 96-tip template and primer transfers and 8-tip system for “cocktail” additions (using Screenmaker or Platemaker)

  • Able to dispense to “exotic” plate maps

  • Successful sub-microliter amplification assays

  • Demonstrated lack of carryover

  • Allows pre-dilution scale down of reagents for sequencing

  • Real time QPCR

  • Sequencing

  • Easy to clean using bleach or other disinfectants

  • High throughput plate (kit) replication for molecular diagnostics (Screenmaker or Platemaker)

  • Options for environmental control (Nanodrop)

  • PCR applications developed in collaboration with molecular diagnostics customer

  • Sequencing applications in development with well respected sequencing center

Platforms


Item

Description

Plate Positions

8-Tip Head

16-Tip Head

96-Tip Head

Syringe Channels

1,4, or 8-Tip Additions to all Wells

10808

Nanodrop I stage and fluidics

1

Yes

-

-

8

-

10591

Nanodrop ExtY stage and fluidics

1

Yes

-

-

8

Yes

11638

Nanodrop II stage and fluidics

2

Yes

-

-

8

Yes

12056

Nanodrop Express stage/fluidics

1 or 2

-

Yes

-

16

Yes

11164

Screenmaker 96+8

5

Yes

-

Yes

16

Yes

12027

Platemaker HTS

5

Yes

-

Yes

104

Yes


Software


Item

Description

11727

Nanobuilder

10591

Nanodrop GUI (for Nanodrop only)


Accessories


Item

Description

11193

Reagent refill system (Nanodrop only)

 

Eppindorf tube holder (all platforms)


Specifications


Return-To-Spot Accuracy

0.1 mm

Aspiration Range, 8-Tip Head

0.1-500µL

Dispensing Range (8-Tip Non-Contact)

0.1-40µL

Dispensing Range (96-Tip)

Screenmaker: 0.1-125µL
Platemaker: 0.1-80µL

Dispensing Precision, 8-Tip Head

CV<10% at 100nL, CV<7% at 200nL, CV<5% at 1µL

Dispensing Precision, 96-Tip Head

CV<15% at 100nL, CV<10% at 200nL, CV<5% at 1µL

Dispensing Accuracy, 8-Tip Head

±10% at 100nL, ±7% at 200nL, ±5% at >1 µL

Dispensing Accuracy, 96-Tip Head

Screenmaker: ±10% at 100-500nL, ±5% at >1 500nL
Platemaker: ±10% at 100nL, ±7% at 200nL, ±5% at >1 µL

Dead Volume, 8-Tip head

1.5µL/channel at 1µL across 384-well plate

Dead Volume, 96-Tip head

<1µL/channel

Syringe Capacity

500, 1000µL








Nanodrop II Transfering Sample to a 384-Well Thermocycle Plate

Click here for information...


Free! Innovadyne Information Kit

Click here for information...

News