bioarray solutions at Innovadyne Technologies
Innovadyne liquid handlers address your requirements for low-density bioarray creation, performing precise deposition of multiple reagents in complex dispense patterns into microplates or onto substrates. Our instruments also perform PCR sample preparation and flexibly perform a wide range of other sample preparation steps prior to creation of microarrays by another instrument. Innovadyne’s non-contact dispensing capability coupled with its valve-free fluid path design guarantee precision and reproducibility of results, and excellent long-term reliability. Difficult-to-dispense reagents (such as particulates or beads) and/or costly genetic samples and proteins are readily handled, with very low dead volume and no system degradation. The aspirate/dispense capabilities of the platform also enable rigorous washing to be performed between samples, minimizing cross-contamination.
Classical liquid handlers using contact methods are prone to variable results due to plate and tip irregularities and poor positional accuracy (typically > 100 µm/axis). Innovadyne’s platforms reliably fulfill critical spotting requirements with precisely manufactured motion control (<20 µm return to spot accuracy) and high-precision non-contact solenoid dispensing.
Flexible aspirate and dispense programmability, such as single-tip, random access pipetting, augments Innovadyne’s broadcast reagent capabilities. In addition to simple reagent additions, complex reagent and template map assemblies are also possible and easily programmed. Innovadyne instruments aspirate from and dispense to a wide variety of plates, reservoirs, reagent trays and Eppendorf style tube holders.
Features (all platforms)
Precise deposition of reagents over a dynamic range of five orders of magnitude, with volumes of 50 nL to 500 µL.
Multiple reagents dispensed sequentially with cross-contamination inherently minimized
Software-configured spot patterns and placement
Accurate spot-on-spot dispensing
Dispense protocols are scaleable, from pilot to large-scale manufacturing
Independent channel spotting enables spotting of unique dispense maps
Easy to maintain and clean
Flexible aspirate and dispense settings
User defined syringe speeds and pressure set points
Ability to clean nozzles between runs
Low-dead volumes
96, 384, 1536, 3456 plates (including low-profile and deep well)
User-friendly software
Simple to integrate with drivers available from most integrators
Platforms
Item |
Description |
Plate Positions |
8-Tip Head |
16-Tip Head |
96-Tip Head |
Syringe Channels |
1,4, or 8-Tip Additions to all Wells |
10808 |
Nanodrop 8-channel fluidics only |
- |
- |
- |
- |
8 |
- |
10808 |
1 |
Yes |
- |
- |
8 |
- |
|
10591 |
1 |
Yes |
- |
- |
8 |
Yes |
|
11638 |
2 |
Yes |
- |
- |
8 |
Yes |
|
12056 |
1 or 2 |
- |
Yes |
- |
16 |
Yes |
|
11164 |
5 |
Yes |
- |
Yes |
16 |
Yes |
|
12027 |
5 |
Yes |
- |
Yes |
104 |
Yes |
Software
Item |
Description |
11727 |
|
10591 |
Nanodrop GUI (for Nanodrop only) |
Accessories
Item |
Description |
11193 |
|
|
Wide-bore tip set (200 µm) (all platforms) |
Specifications
Return-To-Spot Accuracy | 0.1 mm |
Aspiration Range, 8-Tip Head | 0.1-500µL |
Dispensing Range (8-Tip Non-Contact) | 0.1-40µL |
Dispensing Precision, 8-Tip Head | CV<10% at 100nL, CV<7% at 200nL, CV<5% at 1µL |
Dispensing Accuracy, 8-Tip Head | ±10% at 100nL, ±7% at 200nL, ±5% at >1 µL |
Dead Volume, 8-Tip head | 1.5µL/channel at 1µL across 384-well plate |
Syringe Capacity | 500, 1000µL |