IC50 solutions at Innovadyne Technologies
IC50 assays are a commonly used method for assessing drug efficacy in pharmaceutical screening regimens. Typically, these assays are performed via serial dilutions of DMSO compound libraries to achieve dilutions of 2x107 in 100% DMSO. Subsequent to the DMSO serial dilution, assays are performed with each dilution to ascertain the IC50 of the compound of interest.
Innovadyne liquid handlers can be readily configured to make serial dilutions of compounds in DMSO and perform subsequent IC50 screening. Innovadyne’s technology is well suited to the performance of the dilution plates and the screens due to the hybrid syringe/solenoid aspirate and dispense architecture. DMSO is readily handled with the use of double air gaps and an intermediary DMSO solvent plug that acts as a buffer between the DI water-based system fluid and the DMSO sample.
The design allows a user to perform a serial dilution series using the traditional liquid handling, syringe-based component for aspirating, mixing and dispensing. IC50 screens can be run at low volumes using the solenoid-based, non-contact dispense component. Using the Nanodrop II it is possible to perform the required DMSO dilutions and follow the dilution protocol with screens utilizing the second plate position. Alternatively, a pre-diluted plate may be placed in one plate nest with iterative protocols performed using the second plate nest and a plate feeding device. Integration drivers for a variety of plate handlers are commercially available.
In the application note "Developing a Sterile, Reliable Laboratory Setup for Low-Volume Tuberculosis Antibiotic Discovery Assays", developed with the Novartis Institute for Tropical Diseases (Singapore), Novartis tested a Nanodrop II's performance in dispensing 90% v/v DMSO/water. The average precision (% CV) was 6.19, 2.76 and 3.16 for 250, 500 and 1000nL volumes respectively and the accuracy for all volumes showed a deviation from expected volume transferred of less than 10%.
Subsequently a total of 100 96-well plates were dispensed over a 6-week period to screen 8800 compounds from the Novartis compound archive against Calmette-Guerin mycobacterium, with control plates consisting of a streptomycin dose-response curve (11 concentrations from highest concentration of 20µM diluted serially 2-fold in 90% DMSO/water). The dispensing results are as shown:
|
|
Avg. signal-to-background, 100 plates | 10.1 |
Avg. z-factor, 100 plates | .89 |
Features (all platforms)
DMSO compatible system material
Valve-free fluid path isolates valves and syringes from solvents
Syringe aspirate and dispense for serial dilutions
Solenoid dispense for assays reduces total assay volumes
Easy to maintain and clean
Flexible aspirate and dispense settings
Low-dead volumes
Large dynamic volume range: 100 nL-40 uL
96, 384, 1536, 3456 plates (including low-profile and deep well)
User-friendly software
Simple to integrate with drivers available from most integrators
Platforms
Item |
Description |
Plate Positions |
8-Tip Head |
16-Tip Head |
96-Tip Head |
Syringe Channels |
1,4, or 8-Tip Additions to all Wells |
11638 |
2 |
Yes |
- |
- |
8 |
Yes |
|
12056 |
1 or 2 |
- |
Yes |
- |
16 |
Yes |
|
11164 |
5 |
Yes |
- |
Yes |
16 |
Yes |
|
12027 |
5 |
Yes |
- |
Yes |
104 |
Yes |
Software
Item |
Description |
11727 |
|
10591 |
Nanodrop GUI (for Nanodrop only) |
Accessories
Item |
Description |
11193 |
|
11731 |
Specifications
Return-To-Spot Accuracy | 0.1 mm |
Aspiration Range, 8-Tip Head | 0.1-500µL |
Dispensing Range (8-Tip Non-Contact) | 0.1-40µL |
Dispensing Range (96-Tip) | Screenmaker: 0.1-125µL |
Dispensing Precision, 8-Tip Head | CV<10% at 100nL, CV<7% at 200nL, CV<5% at 1µL |
Dispensing Precision, 96-Tip Head | CV<15% at 100nL, CV<10% at 200nL, CV<5% at 1µL |
Dispensing Accuracy, 8-Tip Head | ±10% at 100nL, ±7% at 200nL, ±5% at >1 µL |
Dispensing Accuracy, 96-Tip Head | Screenmaker: ±10% at 100-500nL, ±5% at >1 500nL |
Dead Volume, 8-Tip head | 1.5µL/channel at 1µL across 384-well plate |
Dead Volume, 96-Tip head | <1µL/channel |
Syringe Capacity | 500, 1000µL |